Hi pot test procedure pdf files

Hipot test connection diagram the hipot test is set up by connecting the two output leads of the tester to the device under test. A dielectric withstand test or high potential or hipot test is an electrical test performed on a component or product to determine the effectiveness of its insulation. The megger insulation tester is essentially a highrange resistance meter ohmmeter with a builtin directcurrent generator. The test is conducted under typical roomambient 20 c, 50% rh conditions. This is primarily due to the availability of other test methods and the high levels of power consumption. Dc hipot tester hipot test procedure electrom instruments. Larger test specimens, with high capacitance density, may take more time than expected to discharge.

Hipot testing is an abbreviation for high potential testing a category of electrical tests used to verify the effectiveness of electrical insulation in transformers, motors, printed circuit boards, electrical sub. The test may be between mutually insulated sections of a part or energized parts and electrical ground. Reverse side of card at right is used to record the test data. Remove ground fault circuit breaker before hipotting occurs on the circuit or.

Test and inspection records shall be submitted to the engineer no later than thirty days after completion of the individual test and prior to energizing of equipment. The test is a means to qualify a devices ability to operate safely during rated electrical conditions. Misinterpretation of the relevant standard may result in the product being subjected to a hipot design verification test to the levels described above. Hipot test is the most common type of electrical safety test. Transformer hipot testing ieee electrical code issues. In cases when subsequent application of the test potential is specified in the test routine, it is recommended that the succeeding tests be made at reduced potential. Ac hipot testing there are no widely accepted test standards for ac hipot testing of cables, and power frequency ac hipot testing of cable systems is rarely performed.

What ever the name, the purpose is to detect failure of the insulation system that separates the current carrying portions of an electrical device from any exposed conductive components. Performed by stressing the insulation of the product far. The description of these tests will not apply to watercooled stator windings since the test procedure and analysis differ for watercooled units. Hilo programmable during test time lo can be set to off during hipot test hi can be set to off during ir test indication. As we know,a multimeter or ohm meter reading only can determine if a motor winding is open or shorted but cannot checked winding insulation condition if shorted with ground or phase. The hipot test the dielectric voltagewithstand test is commonly known as the hipot test. In all cases, prior to purchasing new equipment, you should determine the usage, requirements, demand, and calibration of such equipment. Do not subject to megger, high voltage or hipot test. This is a major test and determines the condition of the insulation. The power spply provides current to the module, generally through the precision shunt shown here. Supply technical manual based on our 22year experiences in designing, manufacturing, and selling switching power supplies as well as the latest safety regulations and textbooks. Dc hipot test the dc hipot test is normally not made for ac electrical switchgear and therefore may be considered only when ac hipot cannot be performed. Add a fixed amount of virus to every well of a 96well plate, equivalent to 4 ha units varies according to the virus, except for the serum. In order to pass the hipot test, the production folks must make sure that they made it like the design engineer designed it.

This discussion will also focus on testing of stator windings and not on testing individual bars or coils. If a hi pot test high potential insulation test must be performed, follow the precautions and procedure in nema mg1 and mg2 standards to avoid equipment damage. Rpm insulation systems evaluation and maintenance guidelines. Connect the ground lead of the hipot tester to a suitable building ground or grounding electrode conductor. One safe and effective testing method offered by industrial tests, inc. These tests include a simple ac withstand test and diagnostic testing like tan deltapower factor measurement and partial discharge analysis. Ipctm650 embedded devices test methods subcommittee. The dc voltage potential in the windings is rapidly raised to a predetermined level, or raised in steps up to this level, depending on what test method is used. The dc hipot withstand test is a passfail test that has been applied to all types of cable and accessories. In the event of an emergency, someone outside the test area can hit the estop button to immediately cut off power to the entire test station. It is then maintained at this value for one to ten minutes 3. Meanwhile, your heart palpitation unregulated and blood pressure falling down causes tragedy cant be redeemed.

Figure 14 shows the test setup for the newer highcurrent continuity test. Electrical safety in the workplace 3 and the methods to protect against them. The main purpose of the hi pot tester is to verify the quality and integrity of the electric. It will assist in the interpretation of requirements for this testing and provide broad. The standard test may cause damage to led drivers that contain movs metal oxide varistors that are connected between the power leads and ground for transient suppression and protection. Determine the loto procedure applicable to a given facility, operation, equipment.

The complete guide to electrical insulation testing. Figure 4typical record of insulation resistance of a mill motor. Image you are bathing in bath tube, suddenly drier in operating dropping into bath tube, the current flows from drier through your body to ground under this situation. This guide provides a general overview of the regulatory framework and approval process and explores the specific manufacturing responsibilities and test procedures associated with electrical safety testing. For good insulation, the resistance usually reads in the megohm range. Clampon type ammeters do not require the circuit to be opened for insertion of the meter. While this statement indicates a possible negative effect from repeat hipot testing, cirris has performed experiments to observe any effects of repeated hipot in a device that. Figure 3typical scale on the megger insulation tester. Vlf testing of shielded power cables by paul brooker, consultant to techrentals division of tr corporation. Regulatory agencies have an alternate test for luminaires that have led drivers that are configured this way. For products terminated in a threepronged line cord known as class i.

High potential stress test procedure bcp systems, inc. The limited approach boundary for this hipot procedure at volts is 5 ft. Hipot test, dielectric withstand test, insulation leakage and breakdown test, shorts check, ground check and others. Electrical safety testing reference guide touch area. Ieee std 400 provides additional information on dc testing and evaluation of the insulation of shielded power cable systems c. Test procedures it is our recommendation that if cables are being tested for gross installation defects on a new installation, then a dc hipot test is a viable test procedure. Nonconductive work bench dut safety enclosure wired to the hipot testers remote safety interlock, this protects you from touching the dut while a test is in progress.

The megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. The purpose of the routine test is to determine that the production folks covered all their bases. The conventional dc hipot test is considered a passfail test similar to the ac test. Acceptable procedures for conducting hipot testing, although varying slightly in technique, have been standardized as either a withstand test or a timeleaking current test. How dc hipot works dc voltage is applied to open disconnected windings by the hipot tester or motor analyzer. The dc hipot leakage current technique, sometimes referred to as a megger test, involves the. Ac hv test value should not surpass 75% of the factory test value. Test procedures manual american radio relay league. Only authorized personnel necessary to complete the test should be permitted inside the test area.

The detailed test procedures can be found in ieee standard 95. A hipot test starts with all of the points in a cable held at 0v. At jpl the test is ordinarily run with and without handling forces applied. The voltage is slowly increased to a predetermined overpotential value.

Then a single wire or network of connected points called a net is disconnected from 0v and connected to the ac source see figure 2. Designed to verify that the insulation of a product is adequate enough to withstand high voltage. Between contacts and shielded, the puncture voltage must not less than 1. Sci is a leading manufacturer of electrical safety testing instruments including multifunction electrical safety testers, hipot testers, ground bond testers and insulation resistance testers. The purpose of the dielectric withstand hipot test is to determine whether the insulation from the primary circuit to grounded or accessible parts has sufficient electric strength to withstand the normal overvoltages which could occur in service. Neta test forms tests performed by testing organization. When we need to evaluate the motor condition,hipot tester or high potential tester is the common equipment are used. How to conduct a hipot test on a 11kv cable answer prabhu krishna. Hipot tests this test normally done by licensed electricians or test specialists after continuity and insulation. The ac hipot test values for voltages up to 69 kv are presented in table 1. Overview testing voltage determination and procedure. Not for use in portable or cordconnected applications. Describe the facilitys lockouttagout loto procedure including requirements and activities in the procedure and identify the persons responsible for each activity. All tests shall be performed with the equipment or material deenergized, except where.

Prepare twofold dilutions of patienttest serum to be tested e. Using the right diagnostic tester keeps equipment operational so that users are able to ascertain whether insulation is functioning properly. Unless the type test was marginal, the routine test, in the end, finds gross defects in the manufacturing process. Sentry plus series hipot testers instruction manual. However, in many cases these tests are not performed, even the basic ac hipot test, because the power required from the test set to charge the capacitance of a large coil can be very high, making the. Dry testing transformer series is produced, it is completely changed by the backward state of old test transformer stupid, big and heavy, it can produce our matching mounted on a highvoltage silicon stack to provide dc highvoltage test power supply, with a control box,automatic protection microammeters, gap and other ancillary equipment. Hipot testing can be conducted with a dc potential or ac potential and can be applied as a type 1, withstand test or a type 2, diagnostic test. Follow the steps below to ensure that your tester is properly connected. The hipot testing of switchgear involves testing of the circuit breakers and switch gear buses separately. When ac hipot tests are used for routine maintenance, the power transformer can be examined at rated voltage for 3 min instead of testing at 65% of factory test voltage. Unfortunately, that is not documented in our test procedures. However, the standards state that production hipot testing should not exceed 1,500vac, or its dcrectified equivalent of 2,121vdc, from input to output or input to. Do not use an induction oven to heat noise tested bearings.